| ³í¹®¸í |
»ç¸·±âÈÄ ½º¸¶Æ®ÆÊ Àû¿ë ³Ã¹æÆÐŰÁö½Ã½ºÅÛÀÇ ³Ã¹æÈ¿°ú ºñ±³ºÐ¼® / A Comparison of Cooling Effect of Cooling Package System with Desert Climate Smart Farm |
| ÀúÀÚ¸í |
ÃÖ½½°Ç(Sul Geon Choi) ; Ȳµ¿°ï(Dong Kon Hwang) ; ¹ÚµÎ¿ë(Doo Yong Park) |
| ¼ö·Ï»çÇ× |
¼³ºñ°øÇÐ³í¹®Áý, Vol.33 No.12 (2021-12) |
| ÆäÀÌÁö |
½ÃÀÛÆäÀÌÁö(682) ÃÑÆäÀÌÁö(9) |
| ÁÖÁ¦¾î |
½º¸¶Æ®ÆÊ; ÇǺ¹Àç; Â÷¾ç; ÆÒ¾ØÆÐµå; ½Ç³»Á¶µµ; ³Ã¹æºÎÇÏ ; Smart farm; Covering materials; Shading; Fan & Pad; Indoor illuminance; Cooling load |
| ¿ä¾à1 |
º» ¿¬±¸¿¡¼´Â »ç¸·±âÈÄÁö¿ªÀÇ ¿Â½Ç¿¡¼ Àû¿ë °¡´ÉÇÑ ±â¼úÀ» Á¶»çÇÏ¿© EnergyPlus 8.9¸¦ ÀÌ¿ëÇÏ¿© ½Ã¹Ä·¹À̼ÇÇÏ¿´´Ù. ÇǺ¹ÀçÀÇ Á¾·ù¿¡ µû¶ó Æò±Õ ½Ç³»Á¶µµ¿Í ÃÖ´ë ³Ã¹æºÎÇϸ¦ ºñ±³ÇÏ¿´´Ù. ÇǺ¹Àç°¡ °æÁúÆÇ(PMMA)ÀÏ °æ¿ì ÀÛ¹°ÀÇ ±¤·® ¸ñǥġ¸¦ ¸¸Á·ÇÏ¸é¼ ÃÖ´ë ³Ã¹æºÎÇϸ¦ Àú°¨ÇÒ ¼ö ÀÖ´Â °ÍÀ¸·Î ³ªÅ¸³µ´Ù. ¹Ý¸é ¿ÜºÎÂ÷¾ç±îÁö Àû¿ëÇßÀ» °æ¿ì Æò±Õ ½Ç³»Á¶µµ°¡ Â÷±¤À²¸¸Å ÁÙ¾îµé±â ¶§¹®¿¡ Àç¹è ÀÛ¹°¿¡ ¿µÇâÀ» ÁÙ ¼ö ÀÖÀ» °ÍÀ¸·Î ÆÇ´ÜÇÏ¿© ¿ÜºÎÂ÷¾çÀÇ ÃÖÀû Â÷±¤À²À» 40%·Î Á¤ÇÏ¿´´Ù. ÆÒ¾ØÆÐµå ½Ã½ºÅÛ±îÁö Àû¿ëÇßÀ» °æ¿ì ÆÒ¾ØÆÐµå ½Ã½ºÅÛ È¿À²ÀÌ 60%ÀÏ ¶§ º¸ÆíÀûÀÎ À¯¸®¿Â½Ç Case 1 ´ëºñ 42.9% ÃÖ´ë ³Ã¹æºÎÇϰ¡ Àú°¨ÇÏ¿´°í 80%ÀÏ ¶§ ÃÖ´ë 69.4% Àú°¨ÇÏ´Â °ÍÀ¸·Î ³ªÅ¸³µ´Ù. ÃÖ´ë ³Ã¹æºÎÇÏ Àú°¨·®¸¸Å ³Ãµ¿±â, Ãà¿Á¶ µîÀÇ ¿¿ø Àåºñ¿ë·®À» Àú°¨ÇÒ ¼ö ÀÖÀ» °ÍÀ¸·Î ±â´ëµÈ´Ù. ÈÄ¼Ó ¿¬±¸¿¡¼´Â º» ¿¬±¸¿¡¼ Àú°¨µÈ ³Ã¹æºÎÇϸ¦ ÅëÇØ ³Ãµ¿±â, Ãà¿Á¶ µîÀÇ ¿¿ø Àåºñ¿ë·®À» »êÁ¤Çϰí ÇöÀç °ø»ç°¡ ÁøÇà ÁßÀÎ UAEÀÇ ½ÇÁõ ½º¸¶Æ®¿Â½Ç¿¡¼ ½ÇÃøÇÏ¿© ½Ã¹Ä·¹À̼ǰú ½ÇÁ¦ ³Ã¹æºÎÇÏ¿Í ½Ç»ç¿ë·®À» ºñ±³ÇÏ°í °æÁ¦¼º ºÐ¼®À» ÇϰíÀÚ ÇÑ´Ù. |
| ¿ä¾à2 |
The purpose of this study was to shorten the uncultivated period from about 5-6 months to 2 to 3 months. The uncultivated period of 5-6 months was due to midday temperature in the UAE soaring up to 47¡É and the high solar radiation causing problems in crop cultivation. This study intended to compare the effect of reducing high temperature and cooling load of greenhouse through simulation with covering material, external shading, and fan & pad evaporative cooling system to be applied to the UAE smart farm and use it to select equipment capacity such as chiller and cold storage tank. The average indoor illuminance and the peak cooling load were compared according to the type of covering material and the shading rate. When a fan & pad system was applied, the peak cooling load was reduced by 42.9% or 69.4% compared to the typical glass greenhouse (case 1) when the fan & pad system efficiency was 60% or 80%, respectively. It is expected to reduce the capacity of equipment for heat sources such as chiller and cold storage as much as the peak cooling load reduction. |